3.2.7  TONER HOPPER, FACE PLATE, PCU 
Removing Toner Hopper, Face plate, PCU 
 
 
Important: To avoid damaging the toner end sensor, make sure that the main 
power switch is turned off and that the power cord is disconnected from the power 
source before you remove the toner hopper.  
To remove the toner hopper: 
1.  Prepare an open space on the floor for the toner hopper. 
2.  Remove the screws of the toner hopper [A] (
 x3). 
3.  Place your hands under the left and right corners of the toner hopper and 
slowly pull it out on its rails until it stops. 
I
MPORTANT
:
 
T
HE TONER HOPPER CAN EASILY SLIP OFF ITS RAILS
4.  Press the release [B] to drop the support leg [C].  
5.  Confirm that the support leg is down and locked. 
I
MPORTANT
:
 
A
LWAYS MAKE SURE THAT THE SUPPORT LEG IS DOWN AND LOCKED 
BEFORE YOU REMOVE THE TONER HOPPER
6.  Lift the toner hopper off its rails and set it on the floor. 
 
CAUTION 
The toner hopper is heavy! Lift it carefully, make sure that it 
disengages completely from the rails on the left and right,  and 
then set it on the floor. 
 
7.  Push the toner hopper rails into the machine. 
 
 
B132I006A.WMF 
[A] 
[B] 
[C]