Toshiba e-STUDIO4500c/5500c User Manual

Page of 1120
August, 2006 
IMAGE ADJUSTMENTS 
3-177 
 
3.19 IMAGE ADJUSTMENTS 
3.19.1 SCANNING 
Before doing the following scanner adjustments, perform or check the printing 
registration, side-to-side adjustment and the blank margin adjustment. Use a C-4 
test chart to perform the following adjustments. 
Scanner sub-scan magnification 
1.  Place the test chart (C-4) on the exposure glass and 
make a copy. 
2.  Check the magnification ratio.  
3. Use 
SP4008 (Sub Scan Mag) to adjust if necessary. 
Standard: 
±
1.0%. 
 
 
 
 
 
 
Scanner leading edge and side-to-side registration 
1.  Place the test chart (C-4) on the exposure glass and 
make a copy. 
2.  Check the leading edge and side-to-side registration. 
3.  Adjust with the following SP modes if necessary. 
Standard: 0 
±
 2mm.  
 
 
SP mode 
Sub Scan Reg 
SP4010 001 
Main Scan Reg 
SP4011 001 
 
 
 
 
A
 
B146R962.WMF 
B
A
 
B146R963.WMF 
A: Sub-scan magnification 
A: Leading Edge Registration 
B: Side-to-side Registration