RESETS 
5-7 
 
No. 
What It Initializes  Comments 
All Clear 
Initializes items 2 to 15 below. 
Engine  
Initializes all registration settings for the engine and copy 
process settings. 
SCS  
Initializes default system settings, SCS (System Control 
Service) settings, operation display coordinates, and ROM 
update information. 
IMH Memory  
Initializes the image file system.  
(IMH: Image Memory Handler) 
MCS  
Initializes the automatic delete time setting for stored 
documents.  
(MCS: Memory Control Service) 
Copier application 
Initializes all copier application settings. 
7 Fax 
application 
Not used. 
Printer application 
Initializes the printer defaults, programs registered, the printer 
SP bit switches, and the printer CSS counter. (Not used) 
9 Scanner 
application  Initializes the defaults for the scanner and all the scanner SP 
modes. 
10  Web Service/ 
Network application 
Deletes the Netfile (NFA) management files and thumbnails, 
and initializes the Job login ID. 
Netfiles: Jobs to be printed from the document server using a 
PC and the DeskTopBinder software 
11  NCS  
Initializes the system defaults and interface settings (IP 
addresses also), the SmartNetMonitor for Admin settings, 
WebStatusMonitor settings, and the TELNET settings. 
(NCS: Network Control Service) 
14  Clear DCS Setting 
Initializes the DCS (Delivery Control Service) settings. 
15  Clear UCS Setting 
Initializes the UCS (User Information Control Service) settings. 
16  MIRS Setting 
Initializes the MIRS (Machine Information Report Service) 
settings. 
17  CCS 
Initializes the CCS (Certification and Charge-control Service) 
settings.  
 
4.  Press "Execute", then follow the prompts on the display to complete the 
procedure. 
5.  Make sure that you perform the following settings: 
  Do the printer and scanner registration and magnification adjustments (
 
3-19-1 to 3-19-3)  
  Do the touch screen calibration (
 3-20). 
  Refer to the SMC data lists and re-enter any values which had been 
changed from their factory settings. 
 Execute 
SP3820-001 – Manual Process Control Self Check 