Toshiba e-STUDIO4500c/5500c User Manual

Page of 1120
August 2006 
THERMISTORS, THERMOSTATS 
6-139 
Detailed
D
escr
iptions
 
Temperature Control Graph 
 
 
 
Heating Roller Temperature 
 
Hot Roller Temperature 
 
Pressure Roller Temperature 
 
This table shows how temperature control is done in the different operation modes. 
Heating Roller 
Hot Roller 
Pressure Roller 
Mode 
°
°
°
Plain Paper 
B&W 
175 (175)  347 (347) 
160 (120)  320 (248) 
 FC 
175 
(175)  347 (347) 
160 (120)  320 (248) 
Thick Paper 1 
B&W 
175 (175)  347 (347) 
160 (120)  320 (248) 
 FC 
175 
(175)  347 (347) 
160 (120)  320 (248) 
Thick Paper 2 
B&W 
180 
356 
160 (120)  320 (248) 
 FC 
180 
356 
160 
(120)  320 (248) 
OHP B&W 
170 
338 
100 
212 
 FC 
170 
338 
100 
 
212 
Thin Paper 
B&W 
160 (160)  320 (320) 
150 (120)  302 (248) 
 FC 
160 
(160)  320 (320) 
150 (120)  302 (248) 
Idling Start 
160 
320 
 
Ready (machine ready; 
lamps on, rollers turning) 
180 356 
 
165 329 
Standby (between jobs) 
177 
351 
145 
269.6 
152 306 
Low Power Mode 
-185 -333 -50 
-90 -60  -108 
Energy 
Save 
Off Mode 
Off 
Off 
Off 
 
Notes:  
The parentheses indicate the temperatures for duplexing. Example: 150 (120) 
120
°
C during duplexing. 
If a part of the table is blank, it means that the lamp is not used. For example, the 
hot roller lamp is only used during standby (between jobs). 
 
 
 
B132D131.WMF 
CPM Down 
Power ON 
Idling Start 
Machine Ready 
Job Start 
Job End 
Standby Standby