Toshiba e-STUDIO2500c/3500c/3510c User Manual

Page of 400
Simple Troubleshooting    377
The copy image is fogged.
There is a slight gap 
between the original glass 
and the original.
Lower the Platen Cover (optional) or the 
Automatic Document Feeder (optional) 
fully so that the original will contact with 
the original glass.
The copy image is partially 
missing.
The size or direction of the 
copy paper and the original, 
or the reproduction ratio is 
not set properly.
Use copy paper of the same size as the 
original or set the reproduction ratio suit-
able to the copy paper size.
The copy image has black 
streaks in a horizontal direc-
tion.
The scanning area or guides 
are stained.
Clean them. 
The main charger is dirty.
Clean the main charger.
The copy image has white 
streaks in a horizontal direc-
tion.
The slit glass is dirty.
Clean the slit glass.
The density level of the copy 
image is uneven in a horizon-
tal direction.
The main charger is dirty.
Clean the main charger.
Phenomenon
Usual cause
Countermeasure