Toshiba e-STUDIO451c User Manual
e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 82
3.13.4
Adjusting the tension of the stack processing motor belt
(1) Remove the right inner cover and the rear cover.
(2) Remove the 2 mounting screws, and detach
(2) Remove the 2 mounting screws, and detach
the grip unit.
Fig.3-75
(3) Loosen the screw on the tension arm plate.
(The tension arm plate will be pulled under
tension by the tension spring.)
tension by the tension spring.)
Fig.3-76
Screw
Grip unit
Screw
Screw
Tension arm plate