Omega 3400 User Manual

Page of 26
M-4271/0707, pg. 12 of 26 
e)  Connections For The 15 D Sub Connector 
 
Using a suitable mating connector the pins of the integrated connector 
should be wired as follows: 
 
Connecting To The Integrated 15 Pin Connector 
 
 
 
PIN 7 should be connected to the Positive of the power source.  
 
PIN 5 should be connected to the Negative ( Ground ) of the power 
source. 
 
PIN 2 provides the signal output and should be connected to the positive 
terminal of the display, data acquisition system or voltmeter. 
 
PIN 10 is the signal negative (ground) and should be connected to the 
negative (Ground) terminal of the display, data acquisition system or 
voltmeter. 
 
Pin 8 is the input signal and should be connected to the positive terminal 
of the voltage source. The (0-5VDC) voltage control signal should be 
supplied from a low impedance source.  
 
Pin 1 is the input signal negative (ground) and should be connected to 
the negative (Ground) terminal of the voltage source. 
 
Pins 3, 4, 6, 9, 11, 12, 13, 14 and 15 are not used. 
 
 
Caution: Avoid high voltage static discharges to the input signal 
connection. Do not short the output signal pins or allow them to 
contact the power connections at any time. DAMAGE WILL 
RESULT!  
 
Pin Out of Integrated  
Connector