Omega 3400 User Manual

Page of 26
M-4271/0707, pg. 11 of 26 
d)  Connections For The 9 Pin D Sub Connector 
 
Using a suitable mating connector the pins of the integrated connector 
should be wired as follows: 
 
Connecting To The Integrated 9 Pin Connector 
 
 
 
PIN 3 should be connected to the Positive of the power source.  
 
PIN 4 should be connected to the Negative ( Ground ) of the power 
source. 
 
PIN 2 provides the signal output and should be connected to the positive 
terminal of the display, data acquisition system or voltmeter. 
 
PIN 8 is the signal negative (ground) and should be connected to the 
negative (Ground) terminal of the display, data acquisition system or 
voltmeter. 
 
Pin 6 is the input signal and should be connected to the positive terminal 
of the voltage source. The (0-5VDC) voltage control signal should be 
supplied from a low impedance source.  
 
Pin 7 is the input signal negative (ground) and should be connected to 
the negative (Ground) terminal of the voltage source. 
 
Pins 1, 5, and 9 are not used. 
 
 
Caution: Avoid high voltage static discharges to the input signal 
connection. Do not short the input/output signal pins or allow 
them to contact the power connections at any time. DAMAGE 
WILL RESULT!  
Pin Out of Integrated  
Connector