Omega 3400 User Manual

Page of 26
M-4271/0707, pg. 9 of 26 
b)  Connecting The 6 Pin Mini Din Connector 
 
Using a suitable mating connector the pins of the integrated connector 
should be wired as follows: 
 
Connecting To The Integrated 6 Pin Connector 
 
 
 
Pin 2 should be connected to the Positive of the power source.  
 
Pin 6 should be connected to the Negative (Ground) of the power source. 
 
Pin 3 provides the signal output and should be connected to the positive 
terminal of the display, data acquisition system or voltmeter. 
 
Pin 1 is the signal negative (ground) and should be connected to the 
negative (Ground) terminal of the display, data acquisition system or 
voltmeter. 
 
Pin 4 provides the input signal and should be connected to the positive 
terminal of the voltage source. The (0-5VDC) voltage control signal should 
be supplied from a low impedance source.  
 
Pin 5 is the input signal negative (ground) and should be connected to 
the negative (Ground) terminal of the voltage source. 
 
 
Caution: Avoid high voltage static discharges to the input signal 
connection. Do not short the input/output signal wires or allow 
them to contact the power wires at any time. DAMAGE WILL 
RESULT!  
 
Pin Out of Integrated  
Connector