6.Command Specification 
WRITE FILEMARKS
 
 
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
6-110 
6.32.  WRITE FILEMARKS 10h 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Operation Code (10h) 
Obsolete Reserved 
WSmk 
Immed 
(MSB)  
 
 
Number of File-marks or Set-marks 
 
  
(LSB) 
Control 
WRITE FILEMARKS causes the specified number of File-marks or Set-marks to be written, beginning at the current 
logical position on tape. 
WSmk: If this bit is set, the drive writes a Set-mark to tape instead of a File-mark. 
Immed:  If this bit is set, the drive returns status as soon as the Command Descriptor Block has been validated. An 
Immediate bit of ZERO indicates that status will not be returned until the operation has completed.  
Number of File-marks or Set-marks: This is the number of consecutive marks to be written to tape. A value of 
ZERO is not considered an error and GOOD status is returned. 
This command may be used to force the drive to write any buffered data to the tape. The requested mark(s) will be 
appended to the data and the write buffer will be flushed to tape. A ZERO value in the Number of File-marks field 
indicates that no File-marks are to be written to the tape but the write buffer is still flushed to tape. 
If EOT is detected while writing the marks, the drive will finish writing any buffered data. The command will terminate 
with CHECK CONDITION status. Within the Sense data, the EOM bit is set, the Sense Key field is set to NO SENSE 
and the Additional Sense Code and Additional Sense Code Qualifier fields are set to EOM/P detected. The drive will 
attempt to complete any subsequent WRITE FILEMARKS, returning a CHECK CONDITION status in each case. 
If the drive encounters the physical EOM when attempting a WRITE FILEMARKS, CHECK CONDITION status is 
returned. Within the Sense data, the EOD and Valid bits are set and the Sense Key field is set to VOLUME 
OVERFLOW. The Information fields contain the residue count and the Additional Sense Code and Additional Sense 
Code Qualifier fields are set to EOM/P Detected. The tape is physically positioned at EOM/P.