7.Drive Diagnostics
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
7-1
7. Drive Diagnostics 
This clause deals with the diagnostics supported by the SDX-800V. Each diagnostic is described in detail and 
possible error codes are discussed. 
7.1.  Overview 
The diagnostic firmware for this product is designed to achieve the following objectives: 
- Isolate hardware failures 
- Verify the media 
- Provide predictive information which can lead to the early detection of potential problems 
- Provide remote support capabilities 
- Satisfy manufacturing testing needs 
How these objectives are achieved: 
- Fault isolation is achieved by providing an extensive set of diagnostic tests. 
- Media verification is achieved by error rate testing and tape logs. 
- Predictive data is provided in the form of a tape log and runtime error logs. Logs are maintained within the drive's 
RAM, EEPROM and on the AIT cassettes. 
- Remote support capability is provided by allowing all tests and test sequences to be initiated via the host interface. 
Similarly, all test results are reported back to the host via the interface. 
- Manufacturing needs are satisfied by providing unrestricted access to all internal tests. 
7.2. Diagnostic Test 
This clause describes the Diagnostic Test facilities of the drive. The method for executing tests and receiving test 
results from the Host is described and a full list of available tests and possible result messages is given. 
Diagnostics can be initiated in several ways: 
- Power-on Self Test 
- Send Diagnostic command initiating a Self Test 
- Send Diagnostic command initiating a specific test or sequence 
Each type of Diagnostics will be described in detail. 
7.2.1.   Power-on Self Test 
Each time power is applied to the drive it will automatically perform a series of diagnostics on itself to insure that the 
basic functions of the drive are performing properly. The power-on Self Test sequence is shown below: 
Power supply voltage exceeds power-up threshold 
61 
Main Processor ROM checksum 
62 
Main Processor Destructive RAM Test 
70 
SDX-800V Controller Register Test 
The following 3 tests are initiated by the Mechanism Controller automatically after power-up and therefore would be 
executing in parallel with the tests listed above. 
20 
Mechanism Controller Microprocessor Test 
30 
Front Panel Check 
79 
Data Compression Functions DMA Line Test 
71 
Buffer RAM Test 
If a failure occurs with any of the power-on diagnostic tests the drive will halt with the Status LED flashing.