19.1  SCSI Control Byte
The Control Byte is the last byte of every CDB. The format of this byte is shown below.
Table 100: SCSI Control Byte
 VU 
  VU stands for Vendor Unique. 
 FLAG** 
 
If Link is zero, Flag must also be zero. If Link is one, Flag may also be one. Typically this bit is used to cause an 
interrupt in the Initiator between linked commands. 
 LINK** 
 
This bit is set to one to indicate that the Initiator desires an automatic link to the next command upon successful com-
pletion of the current command. 
Note: * - The drive ignores the link bit and flag bit in the CDB. 
19.2  Abbreviations
These abbreviations are used throughout the following sections: 
 LUN
Logical Unit Number. An encoded three bit identifier for the logical unit. 
 VU
Vendor Unique bits
 LBA
Logical Block Address 
 RSVD 
Reserved
 MSB
Most Significant Byte 
 LSB
Least Significant Byte
19.3  Byte ordering conventions
In this specification, where it is not explicitly stated, all multi-byte values are stored with the most significant byte first. For 
example, in a 4 byte field, byte 0 will contain the MSB and byte 3 the LSB.
BIT 
6 5 4 3 2 1 0 
VU = 0 
Reserved = 0
FLAG
LINK