Fujitsu MAX3073RC User Manual

Page of 94
 
C141-E237 
7-1 
CHAPTER 7  
Error Analysis  
7.1  Error Analysis Information Collection 
 
7.2  Sense Data Analysis 
 
 
 
 
 
 
This chapter explains in detail how sense data collected from a disk drive is used for troubleshooting.  Sense 
data reflects an error in the disk drive, and helps with troubleshooting. 
A sense key, additional sense code, and additional sense code qualifier, taken from various sense data are 
repeated.  Also in this chapter, troubleshooting is performed using these three codes.  Unless otherwise 
specified, "sense data" means the above three codes.  When sense data is represented as (x-xx-xx), the 
leftmost x is a sense key, the middle xx is an additional sense code, and the rightmost x is an additional sense 
code qualifier. 
 
 
7.1 
Error Analysis Information Collection 
7.1.1 Sense 
data 
 
When HDDs post a CHECK CONDITION status, the current command or queued command is 
cleared.  In such a case, the HDDs generate sense data about the command-issuing INIT.  The INIT 
can read the sense data by reading the sense data added to the response frame of the command where 
an error occurred (Auto Sense  function). 
 
 
7.1.2 
Sense key, additional sense code, and additional sense code qualifier  
 
If an error is detected in a disk drive, the error status is indicated in the sense data collected from the 
disk drive.  Figure 7.1 shows the positions of a sense key, additional sense code, and additional sense 
code qualifier.