Fujitsu MAX3073RC User Manual

Page of 94
Error Analysis 
7-2 
C141-E237 
 
 
 Bit 
6 5 4 3 2 1 0 
Byte 0
Valid 
X‘70’ or X‘71’ (error code) 
1
X‘00’ 
2
0  0 ILI 0 
Sense 
key 
3
 
 
 
 
 
 
 
 
4
 
 
 
 
 
 
 
 
5
 
 
 
 
 
 
 
 
6
 
 
 
 
 
 
 
 
7
X‘28’ (additional sense data length) 
8
 
 
 
 
 
 
 
 
9
 
 
 
 
 
 
 
 
10
 
 
 
 
 
 
 
 
11
 
 
 
 
 
 
 
 
12
Additional sense code 
13
Additional sense code qualifier 
14
X‘00’ 
15
SKSV 
 
 
 
 
 
 
 
16
Sense key-specific information 
17
 
 
 
 
 
 
 
 
18
0 0 0 
Port 
0 0 0 0 
19
CDB operation code 
20
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
47
 
 
 
 
 
 
 
 
 
 
ILI: 
Incorrect Length Indicator 
MSB:  Most Significant Byte 
LSB:  Least Significant Byte 
SKSV: Sense Key Specific Valid 
 
Figure 7.1  Format of extended sense data 
[MSB] 
Detail information 
[LSB] 
[LSB] 
Command-specific information 
Information 
Additional 
information 
Basic 
information 
[MSB]