PMC I/O Voltage Configuration
The onboard PMC sites may be configured to support 3.3V or 5.0V I/O PMC modules. To 
support 3.3V or 5.0V I/O PMC modules, both PMC I/O keying pins must be installed in the 
holes. If both keying pins are not in the same location or if the keying pins are not installed, the 
PMC sites will not function. Note that setting the PMC I/O voltage to 5.0V forces the PMC sites 
to operate in PCI mode instead of PCI-X mode. The default factory configuration is for 3.3V 
PMC I/O voltage.
RTM SEEPROM Address Switch (S1)
A 4-position SMT configuration switch is located on the RTM to set the device address of the 
RTM serial EEPROM device. The switch settings are defined in the following table.
10
0 10101
ON
OFF
ON
OFF
ON
OFF
11
1 10100
OFF
OFF
ON
OFF
ON
ON
12
0 10011
ON
OFF
ON
ON
OFF
OFF
13
1 10010
OFF
OFF
ON
ON
OFF
ON
14
1 10001
OFF
OFF
ON
ON
ON
OFF
15
0 10000
ON
OFF
ON
ON
ON
ON
16
1 01111
OFF
ON
OFF
OFF
OFF
OFF
17
0 01110
ON
ON
OFF
OFF
OFF
ON
18
0 01101
ON
ON
OFF
OFF
ON
OFF
19
1 01100
OFF
ON
OFF
OFF
ON
ON
20
0 01011
ON
ON
OFF
ON
OFF
OFF
21
1 01010
OFF
ON
OFF
ON
OFF
ON
Table 1-4. Slot Geographical Address Settings (continued)
Slot 
Address
GAP 
GA(4:0)
SW3
SW4
SW5
SW6
SW7
SW8
Table 1-5. RTM EEPROM Address Switch Assignments
Position
SW1
SW2
SW3
SW4
Function
A0
A1
A2
Not Used
OFF
1
1
1