Master Enable #1 [Y/N]
Y
Yes, Setup and enable the Master 
Address Decoder #1. 
Master Starting Address #1
02000000
Base address of the VMEbus resource 
that is accessible from the local bus. 
Default is the end of calculated local 
memory. 
Master Ending Address #1
EFFFFFFF
Ending address of the VMEbus 
resource that is accessible from the 
local bus. Default is the end of 
calculated memory. 
Master Control #1
0D
Works the same as Slave Control #1. 
Default is $0D. 
Master Enable #2 [Y/N]
N
Do not set up and enable the Master 
Address Decoder #2. 
Master Starting Address #2
00000000
Base address of the VMEbus resource 
that is accessible from the local bus. 
Default is $0. 
Master Ending Address #2
00000000
Ending address of the VMEbus 
resource that is accessible from the 
local bus. Default is $0. 
Master Control #2
00
Works the same as Slave Control #1. 
Default is $00. 
Master Enable #3 [Y/N]
N
Do not set up and enable the Master 
Address Decoder #3. 
Master Starting Address #3
00000000
Base address of the VMEbus resource 
that is accessible from the local bus. 
Default is $0. 
Master Ending Address #3
00000000
Ending address of the VMEbus 
resource that is accessible from the 
local bus. Default is $0. 
Master Control #3
00
Works the same as Slave Control #1. 
Default is $00. 
Table A-1.  ENV Command Parameters (Continued)
ENV Parameter and Options
Default
Meaning of Default