Prescaler Control Register 
The prescaler provides the various clocks required by the counters and 
timers in the VMEchip2. In order to specify absolute times from these 
counters and timers, the prescaler must be adjusted for different local bus 
clocks. The prescaler register should be programmed based on the 
following equation. This provides a 1MHz clock to the Tick timers. 
prescaler register = 256–Bclock (MHz) 
For example, for operation at 25MHz the prescaler value is $E7, and at 
32MHz it is $E0. 
Non-integer local bus clocks introduce an error into the specified times for 
the various counters and timers. This is most notable in the tick timers. The 
tick timer clock can be derived by the following equation. 
tick timer clock Bclock / (256–prescaler value
If the prescaler is not correctly programmed, the bus timers do not generate 
their specified values and the VMEbus reset time may be violated. The 
maximum clock frequency for the tick timers is the B clock divided by 
two. The prescaler register control logic does not allow the value 255 
($FF) to be programmed. 