Motorola MVME1X7P User Manual

Page of 316
Programming Model
http://www.motorola.com/computer/literature
4-27
4
Error Logger Register
SBE
SINGLE BIT ERROR is set when the last error logged 
was due to a single-bit error. It is cleared when a 1 is 
written to the ERRLOG bit. The syndrome code reflects 
the bit in error. (Refer to the 
 section.)
MBE
MULTIPLE BIT ERROR is set when the last error logged 
was due to a multiple bit error. It is cleared when a 1 is 
written to the ERRLOG bit. The syndrome code is 
meaningless if MBE is set.
ERA
This bit provides status for a function that is not currently 
used in the MCECC sector.
EALT
EALT indicates that the last logging of an error occurred 
on a DRAM access by an alternate (MI
 not asserted) 
local bus master.
ESCRB
ESCRB indicates the entity that was accessing DRAM at 
the last logging of a single- or double-bit error. If ESCRB 
is 1, it indicates that the scrubber was accessing DRAM. 
If ESCRB is 0, it indicates that the local MC680x0 bus 
master was accessing DRAM.
ERD
ERD reflects the state of the local bus READ signal pin at 
the last logging of a single- or double-bit error. ERD = 1 
corresponds to READ = high and ERD = 0 to READ = 
low. ERD is meaningless if ESCRB is set.
ADR/SIZ
1st $FFF4305C/2nd $FFF4315C (8-bits)
BIT
31
30
29
28
27
26
25
24
NAME
ERRLOG
ERD
ESCRB
ERA
EALT
0
MBE
SBE
OPER
R/C
R
R
R
R
R
R
R
RESET
0 PLS
0 PLS
0 PLS
0 PLS
0 PLS
X
0 PLS
0 PLS