Motorola MVME1X7P User Manual

Page of 316
4-28
Computer Group Literature Center Web Site
MCECC Functions
4
ERRLOG When set, ERRLOG indicates that a single- or a double-
bit error has been logged by this MCECC and that no 
more will be logged until the error is cleared. The bit can 
only be set by logging an error and cleared by writing a 1 
to it. When ERRLOG is cleared, the MCECC is ready to 
log a new error. Note that because hardware duplicates 
control register writes to both MCECCs, clearing 
ERRLOG in one MCECC sector clears it in the other. Any 
available error information in either MCECC should be 
recovered before clearing ERRLOG.
Error Address (Bits 31-24)
This register reflects the value that was on bits 31-24 of the local MC680x0 
address bus at the last logging of an error.
Error Address (Bits 23-16)
This register reflects the value that was on bits 23-16 of the local MC680x0 
address bus at the last logging of an error.
ADR/SIZ
1st $FFF43060/2nd $FFF43160 (8-bits)
BIT
31
30
29
28
27
26
25
24
NAME
EA31
EA30
EA29
EA28
EA27
EA26
EA25
EA24
OPER
R
R
R
R
R
R
R
R
RESET
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
ADR/SIZ
1st $FFF43064/2nd $FFF43164 (8-bits)
BIT
31
30
29
28
27
26
25
24
NAME
EA23
EA22
EA21
EA20
EA19
EA18
EA17
EA16
OPER
R
R
R
R
R
R
R
R
RESET
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS
0  PLS