1-52
Computer Group Literature Center Web Site
Programming Issues
1
DS1 goes inactive). This time should be longer than any expected 
legitimate transfer time on the bus. We normally set it to 256 
µ
sec. This 
timer can also be disabled for debug purposes.
Before a single-board computer access to another single-board computer 
can complete, however, the VMEchip2 on the accessed board must decode 
a slave access and request the Local Bus of the second board. When the 
Local Bus is granted (any in-process onboard transfers have completed), 
then the Local Bus timer of the accessed board starts. Normally, this is also 
set to 8 
µ
sec. When the memory has the data available, a transfer 
acknowledge signal (TA) is given. This translates into a DTACK signal on 
the VMEbus which is then translated into a TA signal to the first requesting 
processor, and the transfer is complete.
 If the VMEbus global timer expires on a legitimate transfer, the VMEbus 
to Local Bus controller in the VMEchip2 may become confused and the 
VMEchip2 may misbehave. Therefore the bus timer values must be set 
correctly. The correct settings may depend on the system configuration. 
Indivisible Cycles
The MVME167P and MVME177P single-board computers perform 
operations that require indivisible read-modify-write (RMW) memory 
accesses. These RMW sequences occur when the MMU modifies table 
entries or when the MPU executes one of the single-cycle instructions 
listed in Table 
.
Table 1-15.  Single-Cycle Instructions
MPU
Instructions
MC68040
CAS, CAS2, TAS
MC68060
CAS
CAS2 and misaligned CAS instructions are emulated 
by software (see NOTE)