Motorola MVME1X7P User Manual

Page of 316
Error Conditions
http://www.motorola.com/computer/literature
1-55
1
A hardware error occurs on the VMEbus.
A VMEbus slave reports an access error (such as parity error). 
VMEchip2
An 8- or 16-bit write to the LCSR in the VMEchip2 ASIC causes a local 
BERR
Bus Error Processing
Because different conditions can cause bus error exceptions, the software 
must be able to distinguish the source. To aid in this, status registers are 
provided for every Local Bus master. The next section describes the 
various causes of bus error and the associated status registers. 
Generally, the bus error handler can interrogate the status bits and proceed 
with the result. However, an interrupt may occur during the execution of 
the bus error handler (before an instruction can write to the status register 
to raise the interrupt mask). If the interrupt service routine causes a second 
bus error, the status that indicates the source of the first bus error may be 
lost. Application software must take this possibility into account. 
Error Conditions
This section lists the various error conditions that are reported by the 
single-board computer hardware. A subheading identifies each error 
condition; a standard format provides the following information:
Description of the error
How notification of the error is made
Status register(s) containing information about the error