Motorola MVME1X7P User Manual

Page of 316
Error Conditions
http://www.motorola.com/computer/literature
1-57
1
MPU Local Bus Time-out
DMAC VMEbus Error
DMAC Parity Error
Description:
An error occurred while the MPU was attempting to access 
a local resource.
MPU Notification:
TEA is asserted during the MPU access.
Status:
Bit 7 of the MPU Status and DMA Interrupt Count register 
(actually in the DMAC Status register).
Address 
$FFF40048
Comments:
The Local Bus timer timed out. This usually indicates the 
MPU tried to read or write an address at which there was 
no resource. Otherwise, it indicates a hardware problem. 
Description:
The DMAC experienced a VMEbus error during an 
attempted transfer.
MPU Notification:
DMAC interrupt (when enabled)
Status:
The VME bit is set in the DMAC Status register (address 
$FFF40048 bit 1).
Comments:
This indicates the DMAC attempted to access a VMEbus 
address at which there was no resource or the VMEbus 
slave returned a BERR
 signal.
Description:
Parity error while the DMAC was reading DRAM.
MPU Notification:
DMAC interrupt (when enabled)
Status:
The DLPE bit is set in the DMAC Status register (address 
$FFF40048 bit 5).
Comments:
If the TBL bit is set (address $FFF40048 bit 2), the error 
occurred during a command table access; otherwise the 
error occurred during a data access.