 HOUSTON, TEXAS 77251−1443
PLL and PLL controller (continued)
PLLM Register (0x01B7 C110)
31
28
27
24
23
20
19
16
Reserved
R−0
15
12
11
8
7
6
5
4
3
2
1
0
Reserved
PLLM
R−0
R/W−0 0111
Legend: R = Read only, R/W = Read/Write; -n = value after reset
Table 30. PLL Multiplier Control Register (PLLM)
BIT #
NAME
DESCRIPTION
31:5
Reserved
Reserved. Read-only, writes have no effect.
4:0
PLLM
PLL multiply mode [default is x7 (0 0111)].
00000 =
Reserved
10000
=
x16
00001 =
Reserved
10001
=
x17
00010 =
Reserved
10010
=
x18
00011 =
Reserved
10011
=
x19
00100 =
x4
10100
=
x20
00101 =
x5
10101
=
x21
00110 =
x6
10110
=
x22
00111
=
x7
10111
=
x23
01000 =
x8
11000
=
x24
01001 =
x9
11001
=
x25
01010 =
x10
11010
=
Reserved
01011 =
x11
11011
=
Reserved
01100 =
x12
11100
=
Reserved
01101 =
x13
11101
=
Reserved
01110
=
x14
11110
=
Reserved
01111
=
x15
11111
=
Reserved
PLLM select values 00000 through 00011 and 11010 through 11111 are not supported.