Buffalo Technology TS-RXL User Manual

Page of 157
TeraStation User Manual
148
Error and Warning
Displays the current status when changing the settings or formatting drives.
Examples of LCD
Meaning
SYSTEM Error 
E00
MPU No Response
System is not responding. Unplug the power code of the TeraStation and reboot it. If the 
error still persists, contact BUFFALO’s service center for repair.
DRAM LINES 
E01
DATA Failure
Some parts of internal IC is not working properly. Contact BUFFALO’s service center for 
repair.
DRAM LINES 
E02
ADDRESS Failure
Some parts of internal IC is not working properly. Contact BUFFALO’s service center for 
repair.
RTC Chip  
E03
No RTC Clock
Some parts of internal IC is not working properly. Unplug the power code of the TeraStation 
and reboot it. The error still persists, contact BUFFALO’s service center for repair.
SYSTEM Error  
E04
Can’t Load Krnl!
The firmware is corrupted. Contact BUFFALO’s service center for repair.
WDT 
E05
SYSTEM Stopped
System hung up. Unplug the power code of the TeraStation and reboot it. If the error still 
persists, contact BUFFALO’s service center for repair.
TFTP MODE  
E06
Lost boot image
The firmware is corrupted.
Contact BUFFALO’s service center for repair. Wait for 5 minutes to show “E04” and turn off, 
or press and hold the power button for 10 seconds.
HD ALL 
E07
ALL HD Not Found
Hard disks are not found.
Even if the hard disks are connected but this message is displayed, contact BUFFALO’s 
service center for repair.
UPS 
E10
Dependent Mode
Operating using UPS battery due to the power outage. System will be shut down safely.
Check the power supplied to UPS, and turn TeraStation off if there is no problem on UPS.
SYSTEM 
I10
TOO HOT!
Temperature in the system may be over the limits of warranty. Do not place any object 
around the TeraStation. Or move the TeraStation to the cooler place.
SYSTEM Error 
E11
Fan Failure
There is a problem with the number of fan spinning.
Check if there is any objects or dusts on the fan. If you see any objects or dusts, remove them 
by tweezers or an air duster. The error still persists, contact BUFFALO’s service center for 
repair.
SYSTEM Error 
E12
Cooling Failure
Temperature in the system is over the limits of warranty. Do not place any object around the 
TeraStation. Or move the TeraStation to the cooler place.
RAID Error 
E13
ARRAYx Error
An error occurs in Xth RAID array. When rebooting the TeraStation, it will run as degrade 
mode when RAID 1 or RAID 5 is used. You can use an erroneous drive by rebuilding, but it is 
recommended that you replace the erroneous drive immediately.
RAID Arrayx 
E14
Can’t Mount
Xth RAID array could not be mount. Turn off TeraStation, and turn it on again. If the error still 
persists, rebuild RAID. If the error still persists, contact BUFFALO’s service center for repair.
HDx Error 
E15
Many Bad Sectors
The bad sector in xth hard drive has reached the dangerous zone. Replace Xth hard drive.
HDx Error 
E16
HDx Not Found
Cannot find the Xth hard drive.The Xth hard drive may not connected or may be damaged.
Replace the hard drive.