Use the following command to check the following SONET status 
indicators:
CB5000>  show sonet <slot.phy_num> status
Verify that the display lists status is OK for the following indicators:
Line Current Status
Section Current Status
Path Current Status
Record any indications that are not as expected and proceed to 
Verifying ATM Signalling Functions.
Verifying ATM
Signaling Functions
Use the following procedure to verify ATM signaling functions:
Use the following command to check the UNI Version setting of your 
ATM Backbone SwitchModule:
CB5000>  show atm <slot>
 
interface
Examine the setting of the UNI Version parameter of the ATM 
Backbone SwitchModule. It must match the ATM switch setting to 
which it is connected. The valid settings are:
3_0
3_1
Contact your network supplier for the UNI version setting of the ATM 
switch.
If necessary, reset the UNI Version parameter and corresponding ATM 
signalling times using the following command:
CB5000>  set atm <slot>
 
uni_version 3_1 
 
(or
 3_0
)
If you made any changes in Step 2, reset the module using the 
following command:
CB5000>  reset module <slot>
ATM commands do not take effect until you reset the module. Use the 
DMM RESET MODULE command to enable any ATM parameter changes.