April 1997
Maintenance Object Repair Procedures
Page 10-68
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
NPE Crosstalk Test (#6)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on
a per-port basis. The NPE Crosstalk Test verifies that this port’s NPE channel
talks on the selected time slot and never crosses over to time slots reserved for
other connections. If the NPE is not working correctly, one-way and noisy
connections may be observed. This test is usually only part of a port’s Long Test
Sequence and takes about 20 to 30 seconds to complete.
NPE controls port connectivity and gain, and provides conferencing functions on
a per-port basis. The NPE Crosstalk Test verifies that this port’s NPE channel
talks on the selected time slot and never crosses over to time slots reserved for
other connections. If the NPE is not working correctly, one-way and noisy
connections may be observed. This test is usually only part of a port’s Long Test
Sequence and takes about 20 to 30 seconds to complete.
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
X
ND
Loop Around and Conference Test (#47)
X
ND
Station Status and Translation Audits and Updates Test (#36)
X
X
ND
Table 10-27.
TEST #6 NPE Crosstalk Test
Error
Code
Code
Test
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use the
be busy with a valid call. Use the
display port PCSSpp
command to
determine the station extension. Use the
status station
command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
the port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
1001
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
Continued on next page
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1