Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-138
ASAI-PT 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI 
circuit pack detects that Level 1 has been deactivated on the port. The 
aux data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the Packet Bus, 
thus affecting the conveyance of signalling information over D-channel. 
This error occurs when the Packet Bus transmit FIFO buffer overflows. This 
condition probably indicates a hardware problem as well. The ASAI-PORT 
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for 
both on-board hardware problems and potential off-board Packet Bus 
problems. 
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
Major and Minor alarms may be downgraded to warning alarms based on the value used in the 
set 
options
 command.
Table 10-46.
ASAI-PT Port Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm Level 
ASAI-PORT
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
(a)
Level 1 Status 
Inquiry (#621)
MAJ
2
OFF
test port PCSSpp sh r 2
513 (b)
0
none
(b)
ON
1537 (c)
46210
CRC Error 
Counter (#623)
MAJ
2
OFF
3841 (d)
46208
None
3844 (e)
46223
None
3845 (f)
None
3846 (g)
TEI
None
Continued on next page
Blank
This indicates that the Level 1 Status Inquiry failed.
32773
This is a message from the ASAI-Line circuit pack 
indicating Level 1 has been deactivated.