Maintenance Object Repair Procedures 
Page 10-140
ASAI-PT 
10
BRI Port Local LAN Looparound Test (#618)
This test is destructive.
This test verifies the connectivity of a BRI port across the LAN Bus and executes 
only if the port is out-of-service. The test aborts if calls associated with the port 
are in-progress. Failures of this test indicate either on-board faults associated 
with the ASAI-PT hardware on the circuit pack or problems with the LAN Bus, 
which is used to form connectivity between the switch and the ASAI-PT.
The dotted lines in Figure 10-5 show how a Looparound Test is performed across 
the Packet Bus for the D-channel.
Figure 10-5.
BRI Port Local LAN Looparound Path
1.
D = Destructive; ND = Nondestructive
BRI LINE
CIRCUIT
PACK
PACKET
INTERFACE
PACKET BUS
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . .