Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-155
BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack) 
10
Control Channel Loop Around Test (#52)
Refer to the repair procedure described in the "XXX-BD (Common Port Circuit 
Pack)" Maintenance documentation as Control Channel Loop Around Test (#52).
SAKI Sanity Test (#53)
Refer to the repair procedure described in the "XXX-BD (Common Port Circuit 
Pack)" Maintenance documentation as SAKI Sanity Test (#53).
LANBIC Receive Parity Error Counter Test (#595)
This test is destructive
.
The test reads and clears the LANBIC Receive Parity Error Counter on the circuit 
pack. This counter is incremented by the circuit pack when it detects a parity 
error in data received from the Packet Bus.
These errors may be indicative of a circuit pack problem, Packet Bus problem, or 
a problem with another circuit pack on the bus. This test is useful for verifying the 
repair of the problem.
Table 10-52.
TEST #595 LANBIC Receive Parity Error 
Counter Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test was not received from the circuit 
pack within the allowable time period.
1. If the test aborts repeatedly a maximum of five times, 
reset the circuit pack via the 
busyout board PCSS
 
and 
reset board PCSS
 commands.
2. If the test aborts again, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to 
run this test.
2012
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to fail, escalate the problem.