April 1997
Routine Maintenance Procedures 
Page 5-47
System Features 
5
Analog Tie Trunk Back-to-Back Testing
The TN760B circuit pack can be configured for back-to-back testing (also known 
as connectivity testing) by making translation and cross-connect changes. This 
testing configuration allows for the connection of Tie Trunks back-to-back in the 
same switch to verify the operation of Tie Trunk ports. The tests can be 
performed in either the E & M or simplex modes.
E & M Mode Test Procedure
The procedures to perform the Analog Tie Trunk port test in the E & M mode are 
as follows:
1. At the administration terminal, enter 
list configuration trunks
 command 
to determine which ports are assigned on the Tie Trunk circuit pack.
2. Enter 
display dialplan
 command to determine the Trunk Access Code 
(TAC) format.
3. Enter 
display port xx
 command for all ports defined in Step 1. This action 
displays the trunk groups to which the ports belong (that is, of which the 
ports are members).
NOTE:
See the 
 section in this chapter for 
details on how to remove and replace port circuit packs.
4. Insert the circuit pack back into the slot.
61
Warning tone 
62
Forced music tone
63
Zip tone (first of 2 sent)
64
Incoming call ID (first of 2 sent)
65
Tone on hold
66
CO dial tone
67
Repetitive confirmation tone
68
Conference/bridging tone
Table 5-3.
System Tone Identification Numbers  — 
Continued
Number
Description
Continued on next page