Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-47
System Features
5
Analog Tie Trunk Back-to-Back Testing
The TN760B circuit pack can be configured for back-to-back testing (also known
as connectivity testing) by making translation and cross-connect changes. This
testing configuration allows for the connection of Tie Trunks back-to-back in the
same switch to verify the operation of Tie Trunk ports. The tests can be
performed in either the E & M or simplex modes.
as connectivity testing) by making translation and cross-connect changes. This
testing configuration allows for the connection of Tie Trunks back-to-back in the
same switch to verify the operation of Tie Trunk ports. The tests can be
performed in either the E & M or simplex modes.
E & M Mode Test Procedure
The procedures to perform the Analog Tie Trunk port test in the E & M mode are
as follows:
as follows:
1. At the administration terminal, enter
list configuration trunks
command
to determine which ports are assigned on the Tie Trunk circuit pack.
2. Enter
display dialplan
command to determine the Trunk Access Code
(TAC) format.
3. Enter
display port xx
command for all ports defined in Step 1. This action
displays the trunk groups to which the ports belong (that is, of which the
ports are members).
ports are members).
NOTE:
See the
section in this chapter for
details on how to remove and replace port circuit packs.
4. Insert the circuit pack back into the slot.
61
Warning tone
62
Forced music tone
63
Zip tone (first of 2 sent)
64
Incoming call ID (first of 2 sent)
65
Tone on hold
66
CO dial tone
67
Repetitive confirmation tone
68
Conference/bridging tone
Table 5-3.
System Tone Identification Numbers —
Continued
Number
Description
Continued on next page