Maintenance Object Repair Procedures 
Page 10-507
DIOD-DS1 (DS1 DIOD Trunk) 
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 
Interface circuit pack to assure that the trunk’s translation is correct. Translation 
updates include the following data: trunk type (in/out), dial type, timing 
parameters, and signaling bits enabled. The port audit operation verifies the 
consistency of the current state of trunk kept in the DS1 Interface circuit pack 
and in the switch software.
2053
ABORT
At least one of the following errors is found on the DS1 
circuit pack:
1281
Loss of signal
1793
Blue Alarm
2049
Red Alarm
2305
Yellow Alarm
1537
Hyperactivity
Look for the above error types in the Hardware Error Log 
and follow the procedures given in the appropriate 
DS1-BD or UDS1-BD maintenance documentation for 
the listed error types.
FAIL
The NPE of the tested port did not conference the tones 
correctly. This will cause noisy and unreliable 
connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. 
User-reported troubles on this port should be 
investigated by using other port tests and by examining 
station, trunk, or external wiring.
Table 10-136.
TEST #7 Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation