Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-507
DIOD-DS1 (DS1 DIOD Trunk)
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack
and in the switch software.
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack
and in the switch software.
2053
ABORT
At least one of the following errors is found on the DS1
circuit pack:
circuit pack:
■
1281
—
Loss of signal
■
1793
—
Blue Alarm
■
2049
—
Red Alarm
■
2305
—
Yellow Alarm
■
1537
—
Hyperactivity
Look for the above error types in the Hardware Error Log
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for
the listed error types.
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for
the listed error types.
FAIL
The NPE of the tested port did not conference the tones
correctly. This will cause noisy and unreliable
connections.
correctly. This will cause noisy and unreliable
connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections.
User-reported troubles on this port should be
investigated by using other port tests and by examining
station, trunk, or external wiring.
User-reported troubles on this port should be
investigated by using other port tests and by examining
station, trunk, or external wiring.
Table 10-136.
TEST #7 Conference Circuit Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page