Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-720
FL-DATA (Flash Data Consistency) 
10
a. The Aux Data field records which SPE was active at the time the Flash 
Data Consistency Test failed. An "8" in the log refers to carrier A and a "16" 
refers to carrier B.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Memory Card Insertion Test,
 for example, you 
may also clear errors generated from other tests in the testing sequence.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
1.
D = Destructive; ND = Nondestructive
292, 
324,
388, 
420,
452
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
12 Volt Power Supply Test (#701) (b)
X
X
ND
Memory Card Insertion Test (#695) (a)
X
X
ND
Memory Card Format and Read Test (#696) (a)
X
X
ND
Memory Card Match Test (#697) (a)
X
X
ND
Memory Card Write-Protected Test (#698) (a)
X
X
ND
Memory Card Directory Recovery Test (#699) (a)
X
X
ND
Memory Card Translation Data Integrity Test (#694) (a)
X
ND
Memory Card Erase/Write/Read Test (#693) (a)
X
ND
Flash Data Consistency Test (#421) (c)
X
ND
Table 10-204.
Flash Data Consistency Error Log Entries  — 
Continued
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
Continued on next page