FL-DATA (Flash Data Consistency) 
10
Notes:
a. See “CARD-MEM” for this test description.
b. See “12V-PWR” for a description of this test.
c. The Flash Data Consistency Test does not run in a Standard system.
Flash Data Consistency Check Test (#421)
The software vintage number, translation time stamps, announcement time 
stamps, and update file time stamps and identifiers are read off of both memory 
cards or SPEs and then compared. If the comparison shows any discrepancy, 
FL-DATA is alarmed. This test is only run in a High or Critical Reliability system. 
The test is run as part of the 
test card-mem long
 and as part of the standby PE 
scheduled maintenance.
Table 10-205.
TEST #421 Flash Data Consistency Check Test 
Error 
Code
Test 
Result
Description/Recommendation
0
ABORT
The test timed out without completing. This error can occur when the 
system is heavily loaded and the test is not allocated sufficient time to 
run.
1. Rerun the test when the system is less busy and is not running 
standby maintenance.
1029 
1030 
2011 
2012 
2013 
2014 
2015 
2016 
2017 
2018 
2019 
2020 
2021 
2022 
2023 
2024 
2025 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance documentation 
for a description of these error codes.
Continued on next page