Page 10-777
ISDN-LNK (ISDN-PRI Signaling Link Port)
10
Signaling Link Board Check (#643)
This ISDN-PRI Signaling Link Port D-channel depends on the health of the DS1
Interface circuit pack. This test checks the state of the DS1 Interface circuit pack
transporting the ISDN-PRI Signaling Link Port.
Interface circuit pack. This test checks the state of the DS1 Interface circuit pack
transporting the ISDN-PRI Signaling Link Port.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors present
or some Tone Detectors may be out-of-service.
system may be oversized for the number of Tone Detectors present
or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable
time period.
time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2020
ABORT
The test did not run due to an already existing error on the specific
port or a more general circuit pack error.
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
causes noisy and unreliable connections.
1. Replace the DS1-BD Interface circuit pack.
PASS
The port is able to communicate over the TDM Bus.
Table 10-217.
TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page