Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-777
ISDN-LNK (ISDN-PRI Signaling Link Port) 
10
Signaling Link Board Check (#643)
This ISDN-PRI Signaling Link Port D-channel depends on the health of the DS1 
Interface circuit pack. This test checks the state of the DS1 Interface circuit pack 
transporting the ISDN-PRI Signaling Link Port.
1003
ABORT
The system could not allocate a tone receiver for the test. The 
system may be oversized for the number of Tone Detectors present 
or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to 
TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to 
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a 
maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable 
time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2020
ABORT
The test did not run due to an already existing error on the specific 
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the 
circuit pack and attempt to diagnose the already existing error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This 
causes noisy and unreliable connections.
1. Replace the DS1-BD Interface circuit pack.
PASS
The port is able to communicate over the TDM Bus.
Table 10-217.
TEST #6 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page