Maintenance Object Repair Procedures 
Page 10-903
MET-LINE (MET Line) 
10
MET Line Ringer Update Test (#62)
In this update, a "ringer on" or a "ringer off" message is sent to the firmware to 
start and stop the ringer on the set.
PASS
Hybrid Line Station Audits passed.
1. Although this test always returns a PASS result, it 
may enter Error Types 257 or 513 into the Error Log. 
To determine if there are any problems that don’t 
show up in the test result, look for these error types 
in the Error Log.
2. If these errors appear in the Error Log, or if user 
complaints still exist, investigate by using other 
circuit pack tests, and by examining the station, 
wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the 
list config
 command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to ensure that 
there is a valid board inserted.
Table 10-257.
TEST #61 MET Line Station Audits Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page