Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-903
MET-LINE (MET Line)
10
MET Line Ringer Update Test (#62)
In this update, a "ringer on" or a "ringer off" message is sent to the firmware to
start and stop the ringer on the set.
start and stop the ringer on the set.
PASS
Hybrid Line Station Audits passed.
1. Although this test always returns a PASS result, it
may enter Error Types 257 or 513 into the Error Log.
To determine if there are any problems that don’t
show up in the test result, look for these error types
in the Error Log.
To determine if there are any problems that don’t
show up in the test result, look for these error types
in the Error Log.
2. If these errors appear in the Error Log, or if user
complaints still exist, investigate by using other
circuit pack tests, and by examining the station,
wiring, and connections.
circuit pack tests, and by examining the station,
wiring, and connections.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the
list config
command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board long
command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, check to ensure that
there is a valid board inserted.
the port. If this is not the case, check to ensure that
there is a valid board inserted.
Table 10-257.
TEST #61 MET Line Station Audits Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page