Page 10-976
M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software
and call processing agree on the on-/off-hook status of the Maintenance/Test
Digital Port.
and call processing agree on the on-/off-hook status of the Maintenance/Test
Digital Port.
50
FAIL
The switch was unable to communicate with the port
circuitry used for digital trunk testing.
circuitry used for digital trunk testing.
100
FAIL
Data was not sent from Port 2 to Port 3 successfully in
asynchronous mode.
asynchronous mode.
101
FAIL
Data was not sent from Port 3 to Port 2 successfully in
asynchronous mode.
asynchronous mode.
102
FAIL
Data was not sent from Port 2 to Port 3 successfully in
synchronous mode.
synchronous mode.
103
FAIL
Data was not sent from Port 3 to Port 2 successfully in
synchronous mode.
synchronous mode.
1. Reset the circuit pack via the
busyout board PCSS
,
reset board PCSS
,
release board PCSS
command
sequence.
2. Test the port again via the
test port PCSS02 l
command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test Digital Port digital trunk testing
capability is operating correctly.
capability is operating correctly.