M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software 
and call processing agree on the on-/off-hook status of the Maintenance/Test 
Digital Port.
50
FAIL
The switch was unable to communicate with the port 
circuitry used for digital trunk testing.
100
FAIL
Data was not sent from Port 2 to Port 3 successfully in 
asynchronous mode.
101
FAIL
Data was not sent from Port 3 to Port 2 successfully in 
asynchronous mode.
102
FAIL
Data was not sent from Port 2 to Port 3 successfully in 
synchronous mode.
103
FAIL
Data was not sent from Port 3 to Port 2 successfully in 
synchronous mode.
1. Reset the circuit pack via the 
busyout board PCSS
reset board PCSS
release board PCSS
 command 
sequence.
2. Test the port again via the 
test port PCSS02 l
 
command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test Digital Port digital trunk testing 
capability is operating correctly.