Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-997
OPS-LINE (DS1 OPS Line) 
10
DS1 OPS Switchhook Inquiry Test (#312)
This test initiates the Switchhook Audit Test. The test queries the switchhook state 
of the Off-Premises-Station in switch software. If the state in switch software 
disagrees with the state on the DS1 Interface circuit pack. The state in the switch 
software is updated to match the state on the DS1 Interface circuit pack.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the 
list config
 command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, dispatch to check to 
ensure that there is a valid board inserted.
Table 10-288.
TEST #312 DS1OPS Switchhook Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-287.
TEST #36 Audit and Update Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page