OPS-LINE (DS1 OPS Line)
10
DS1 OPS Switchhook Inquiry Test (#312)
This test initiates the Switchhook Audit Test. The test queries the switchhook state
of the Off-Premises-Station in switch software. If the state in switch software
disagrees with the state on the DS1 Interface circuit pack. The state in the switch
software is updated to match the state on the DS1 Interface circuit pack.
of the Off-Premises-Station in switch software. If the state in switch software
disagrees with the state on the DS1 Interface circuit pack. The state in the switch
software is updated to match the state on the DS1 Interface circuit pack.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the
list config
command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board long
command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 10-288.
TEST #312 DS1OPS Switchhook Inquiry Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-287.
TEST #36 Audit and Update Test —
Continued
Error
Code
Test
Result
Description/ Recommendation