Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1041
PE-BCHL (PRI Endpoint Port) 
10
Service State Audit (#256)
As is noted in the general description for PRI Endpoint Port, these ports may be 
in one of several service states as defined by the ISDN-PRI Specification. This 
test performs a service state audit with the far-end terminal adapter to ensure 
that both sides agree on the service state.
A PASS for this test simply means that an audit message was successfully 
composed and sent out to the far-end terminal adapter. The ISDN Specification 
allows up to two minutes for a reply. If no reply is received within that two minute 
window, this switch automatically tries once again. If that attempt fails, an error is 
logged (Error Type 3073), and the switch attempts a recovery by automatically 
retrying approximately every 15 minutes. If the port was initially in the INS 
(in-service) state, it is now placed into the MTC/FE (maintenance state, far-end 
problem) state. Until a Service State Audit attempt is successful, no outgoing 
calls are placed over this port, but incoming calls are be accepted. The service 
state of this port does not affect the service state of other ports in the PRI 
Endpoint. If an incoming call that uses this port is presented while in such a state, 
a Service State Audit attempt is immediately attempted (that is, the switch does 
not wait for the 15 minute cycle, but instead tries to recover immediately). To 
investigate the status of this PRI Endpoint Port, issue the 
status pri-endpoint 
<extension>
 command.
4
FAIL
There is a problem with the Signaling Channel and/or with the Processor 
Interface Link.
1. Consult the procedure for the ISDN-PRI Signaling Group (ISDN-GRP) 
and/or the procedures for Processor Interface Link (PI-LINK). Further 
information may also be obtained by consulting the procedures for the 
ISDN-PRI Signaling Channel (ISDN-LNK).
8
FAIL
There is a problem with the UDS1 interface circuit pack.
1. Consult the procedures for UDS1 interface circuit pack (UDS1-BD).
PASS
The signaling link hardware is okay.
Table 10-299.
TEST #255 Signaling Link State Check Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page