Page 10-1159
PR-MAINT (Maintenance Processor) 
10
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does an on-board loop around by 
using the MTPINADS channel. Test data is sent through the on-board modem out 
toward the INADS trunk. The data is looped around before the actual trunk, and it 
comes back into the on-board modem. The data is then verified for integrity.
NOTE:
The test does not send any data onto the INADS trunk. However, in order to 
pass, the test does require the trunk to be present.
10206
ABORT
System could not determine if the testing of the INADS port is administered.
1. Enter the 
change system-parameters maintenance
 command. Verify 
that the "Test Remote Access Port?" field is set to "y."
2. Retry the command at 1-minute intervals a maximum of 5 times.
10208
ABORT
The remote access port is busy. INADS is probably dialed into the switch.
1. If INADS is dialed in, the INADS trunk is working. There is no need to run 
the test.
Table 10-347.
TEST #103 MTP Analog Loop Around Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
(Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.)
Continued on next page
Table 10-346.
TEST #102 MTP Outpulse Relay Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page