Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1161
PR-MAINT (Maintenance Processor) 
10
MTP Dual Port Ram Test (#104)
This test is destructive.
The test terminates any PPN Manager I session, and it is a coordinated test of the 
MTP dual port ram (DPR). The DPR is a section of memory that is shared by the 
MTP and by the 80286/386 Processor circuit pack. Control messages and data 
are passed through the DPR. The test forces both sides to read and write the 
DPR simultaneously in alternate locations.
The DPR test causes the PPN Manager I to log off before the test result is 
displayed. The test result is determined according to the terminal from which the 
test is run. If the test is run from the PPN Manager I terminal, system technician 
should log back in and examine the Error Log for an error against PR-MAINT, 
with Error Type 769, no Aux Data. This error entry indicates that the MTPDPR Test 
failed and that the Processor circuit pack should be replaced.
!
WARNING:
If the TN786B circuit pack must be replaced, and if there is a blank in the 
Expansion Memory circuit pack slot (that is, in the slot immediately to the 
right of the TN786B circuit pack), remove the blank before removing the 
circuit pack. Otherwise, the circuit pack and/or the two connectors that are 
used to connect the Expansion Memory circuit pack (if available) might 
become damaged.
If the test is being run from a terminal other than the PPN Manager I (for example, 
EPN Manager I, remote access, and so forth), the test results are displayed on 
the screen.
10304
FAIL
MTP reported test failure. The system is not able to reliably contact INADS 
with alarm data. The system continues to provide good service.
1. If MTP Outpulse Relay Test (#102) is also failing, check for the 
presence of the INADS trunk, and resolve any INADS trunk problems.
2. If Test #102 passes, the fault is on the Processor circuit pack. The 
circuit pack should be replaced at your convenience.
PASS
MTP detected correct data through the loop back connection.
1. If the system cannot call INADS, or if INADS cannot contact the 
system, check with the local Central Office for problems with the 
INADS trunk, and verify that the INADS number is correct.
Table 10-347.
TEST #103 MTP Analog Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page