Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1343
SYSTEM (System) 
10
SYSTEM (System)
SYSTEM is generally used when software encounters a problem with either 
hardware or itself and requests a restart to clear the problem. For example, if 
there is a loss of clock in a system with high or critical reliability, the system asks 
for a Reset 2 to switch to the other clock. SYSTEM also logs errors that cannot be 
associated with any single process. This is not a problem. The initcauses log 
should also confirm that a software-requested restart was performed.
Error Log Entries and Test to Clear Values
The Aux Data field may be 0 or the return code from a bad software call, and the 
following examples in no way exhaust the possibilities. Often, two errors are 
logged at the same time for each problem.
1.
SYSTEM only has errors associated with it and thus only appears in the Error Log and not 
in the Alarm Log. There are no tests that can be run with SYSTEM.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
Full Name of MO
SYSTEM
None
None
SYSTEM
Table 10-407.
System Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
None
8 (a)
0
None
9 (b)
Any
None
10 (c)
Any
None
21 (d)
None
355 (e)
Any
None
356 (f)
Any
None
601 (g)
None
602 (h)
None
603 (i)
None
9012 (j)
Any
None