Maintenance Object Repair Procedures
Page 10-1343
SYSTEM (System)
10
SYSTEM (System)
SYSTEM is generally used when software encounters a problem with either
hardware or itself and requests a restart to clear the problem. For example, if
there is a loss of clock in a system with high or critical reliability, the system asks
for a Reset 2 to switch to the other clock. SYSTEM also logs errors that cannot be
associated with any single process. This is not a problem. The initcauses log
should also confirm that a software-requested restart was performed.
hardware or itself and requests a restart to clear the problem. For example, if
there is a loss of clock in a system with high or critical reliability, the system asks
for a Reset 2 to switch to the other clock. SYSTEM also logs errors that cannot be
associated with any single process. This is not a problem. The initcauses log
should also confirm that a software-requested restart was performed.
Error Log Entries and Test to Clear Values
The Aux Data field may be 0 or the return code from a bad software call, and the
following examples in no way exhaust the possibilities. Often, two errors are
logged at the same time for each problem.
following examples in no way exhaust the possibilities. Often, two errors are
logged at the same time for each problem.
1.
SYSTEM only has errors associated with it and thus only appears in the Error Log and not
in the Alarm Log. There are no tests that can be run with SYSTEM.
in the Alarm Log. There are no tests that can be run with SYSTEM.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
Full Name of MO
SYSTEM
None
None
SYSTEM
Table 10-407.
System Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
None
8 (a)
0
None
9 (b)
Any
None
10 (c)
Any
None
21 (d)
None
355 (e)
Any
None
356 (f)
Any
None
601 (g)
None
602 (h)
None
603 (i)
None
9012 (j)
Any
None