Maintenance Object Repair Procedures 
Page 10-1359
TAPE (Tape Unit) [G3iV1.1-286] 
10
Tape Translation Status Test (#505)
This test checks whether the TAPE is currently alarmed due to the failure of a 
load translation or save translation attempt on the TAPE.
9000’s
ABORT
Refer to Table A, 
 and follow the recommended repair strategy for 
the specific error code.
Any 
Others
ABORT
Refer to Table B, 
 and follow the recommended repair strategy for 
the specific error code.
PASS
If this test passes, the TN770 Memory and the TN773 
Processor circuit packs are in good working order. This 
is not a test of the tape cartridge or of the TN774 Tape 
Drive circuit pack.
Table 10-413.
TEST #505 Tape Save Translation Status Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
1030 
and 
2011, 
2013
to
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance 
documentation for a description of these error codes.