Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1359
TAPE (Tape Unit) [G3iV1.1-286]
10
Tape Translation Status Test (#505)
This test checks whether the TAPE is currently alarmed due to the failure of a
load translation or save translation attempt on the TAPE.
load translation or save translation attempt on the TAPE.
9000’s
ABORT
and follow the recommended repair strategy for
the specific error code.
Any
Others
Others
ABORT
and follow the recommended repair strategy for
the specific error code.
PASS
If this test passes, the TN770 Memory and the TN773
Processor circuit packs are in good working order. This
is not a test of the tape cartridge or of the TN774 Tape
Drive circuit pack.
Processor circuit packs are in good working order. This
is not a test of the tape cartridge or of the TN774 Tape
Drive circuit pack.
Table 10-413.
TEST #505 Tape Save Translation Status Test
Error
Code
Test
Result
Description/ Recommendation
1029 to
1030
and
2011,
2013
to
2051
1030
and
2011,
2013
to
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
documentation for a description of these error codes.
Continued on next page
Table 10-412.
TEST #230 DMA Latch Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page